Rating AC – 129 dB +/-2 dB (c) at 100 feet per ANSI specifications
70 dB (c) sound coverage of 1.5 mile radius over average terrain
Output Frequency: 500 Hz
Factory sealed motor bearings eliminate lubrication and maintenance.
Fiberglass hood, galvanized steel mounting platforms, and stainless steel hardware to minimize corrosion concerns.
Operating temperatures from -40 C to 60 C and 0 – 100% humidity
240/120 VAC main power
Solar power supply to maintain 48 VAC battery systems
True UPS DC battery back-up power systems are available
21 day battery backup duration
60 minute run time, 3/3 duty cycle, for ASC electro-mechanical sirens
Optional 5 minute on / 5 minute off duty cycle
System Specs
Wide variety of activation options customized for each installation’s unique circumstances
Regulatory Compliance
FEMA CPG 1-17, UL 464, 864
Two-year Factory Parts repair or exchange warranty
Five-year Factory Parts repair or exchange warranty on siren head
For maximum sound dispersion, sirens should be mounted 45′ 55′ above grade. An optional pole mount Is available for mounting the head on a standard wooden utility pole The center mount, low-silhouette siren design eliminates the need for support wires The sirens can also be mounted on proper structures such as roofs, towers, etc Mounting brackets for these applications and additional installation accessories are available from American Signal Corporation.
Environmental Qualifications
Operating Temperature Range: -40 °C to 60 °C
Storage Temperature Range: -65 °C to 125 °C
Humidity 0% – 100% (non-condensing)
Wind Speed 150 MPH
Three tones, cancel, and a local growl test